
Add to Cart
Electric Parameter | | | | | | | ||||||
PCM Specifications For 3.2V (1S) LiFePO4 Battery Packs | | | | | | | ||||||
Model:JW-B1S5A-012 | | | | | | | ||||||
NO. | Project | | Min. | Typ. | Max. | Unit | ||||||
1 | voltage | Charging voltage | | 3.65 | | V | ||||||
| | Balance voltage for single cell | / | / | / | V | ||||||
2 | Current | Balance current for single cell | | | / | mA | ||||||
| | Current consumption | | | 20 | uA | ||||||
| | Maximal continuous charging current | | | 5 | A | ||||||
| | Maximal continuous discharging current | | | 5 | A | ||||||
3 | Over charge protection | Overcharge detection voltage for single cell | 3.725 | 3.75 | 3.775 | A | ||||||
| | Overcharge detection delay time | 0.5 | | 2 | S | ||||||
| | Overcharge release voltage for single cell | 3.55 | 3.60 | 3.65 | V | ||||||
4 | Over discharge protection | Overdischarge detection voltage for single cell | 2.05 | 2.10 | 2.15 | V | ||||||
| | Overdischarge detection delay time | 10 | | 100 | mS | ||||||
| | Overdischarge release voltage for single cell | 2.25 | 2.30 | 2.35 | V | ||||||
5 | Overcurrent protection | Over current detection voltage | 0.185 | 0.2 | 0.225 | V | ||||||
| | Over current detection current | 7 | | 10 | A | ||||||
| | Detection delay time | 5 | | 20 | mS | ||||||
| | Release condition | Cut load,Automatic recovery | | | | ||||||
6 | Short protection | Detection condition | Exterior short circuit | | | | ||||||
| | Detection delay time | 200 | | 500 | μS | ||||||
| | Release condition | Cut load,Auto recovery | | | | ||||||
7 | Resistance | Protection circuitry (MOSFET) | | | 40 | mΩ | ||||||
8 | Temperature | Operating Temperature Range | -40 | | 85 | ℃ | ||||||
| | Storage Temperature Range | -40 | | 1255 | ℃ |